Section 3: Using the RAIDCore Management Software
How to replace a failed drive in a RAID 1 array:
Note: This procedure only applies when there is no I/O from the time the failed disk was removed to the
time the new disk was inserted.
Physically remove the failed hard drive from the machine. The RAIDConsole will display a pop-up
indicating that a drive was removed and a rescan is required. The rescan will remove the drive from the
configuration. Click on RESCAN.
After the Rescan completes you will see the RAID-1 array as critical in the array view, you will also see
that the pulled drive was removed from the disk list.