Pagina 1 - Service Manual

SANnet II 200 FC, SATA, and SATA SEArray Installation, Operation, andService ManualMarch 200583-00003261, Revision C

Pagina 2 - Trademarks

x SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 3 - Contents

6-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20056.2 Front-Panel LEDsThe drive LEDs are located b

Pagina 4

Chapter 6 Checking LEDs 6-3Table 6-2 lists the front-panel LEDs and describes LED activity.Table 6-2 Front-Panel LEDs LED LED Color DescriptionDrive

Pagina 5 - Contents v

6-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – To test that the LEDs work, using a paper

Pagina 6

Chapter 6 Checking LEDs 6-5A similar situation occurs when you add an expansion unit or JBOD and there is a mismatch between the SES or PLD firmware o

Pagina 7 - Contents vii

6-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 6-4 SANnet II 200 SATA Array I/O Control

Pagina 8

Chapter 6 Checking LEDs 6-7The I/O controller module LEDs and their color definitions are shown in Table 6-4.Table 6-4 I/O Controller Module and Batt

Pagina 9 - Contents ix

6-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – Ethernet link LEDs on SANnet II 200 FC, S

Pagina 10

Chapter 6 Checking LEDs 6-9The I/O expansion module LEDs and their color definitions are shown in Table 6-5.Note – An SFP link status (L) LED is off i

Pagina 11

6-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 6-8 AC Power Supply and Fan ModuleThe f

Pagina 12

7-1CHAPTER7Maintaining Your ArrayThis chapter covers the following maintenance and troubleshooting topics: “Using Software to Monitor and Manage the

Pagina 13 - Figures xiii

xiFiguresFIGURE 1-1 SANnet II 200 FC, SATA, and SATA SE Array Front View . . . . . . . . . . . . . . . . . 1–2FIGURE 4-1 Front Bezel and Front Bezel

Pagina 14

7-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005 SANscape Alert provides event monitoring and n

Pagina 15

Chapter 7 Maintaining Your Array 7-3setting up a configuration with redundant pathing. Multipathing software makes multiple paths between the server a

Pagina 16

7-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20057.1.5 The VERITAS Volume Manager ASLVERITAS has

Pagina 17 - How This Book Is Organized

Chapter 7 Maintaining Your Array 7-5Your lithium ion battery should be changed every two years if the unit is continuously operated at 77° F (25° C).

Pagina 18 - Related Documentation

7-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051. From the Main Menu, choose view and edit Even

Pagina 19 - Technical Support

Chapter 7 Maintaining Your Array 7-77.4 Upgrading FirmwareCaution – Be particularly careful about downloading and installing PLD firmware. If the wron

Pagina 20

7-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005A controller that replaces a failed unit in a du

Pagina 21

Chapter 7 Maintaining Your Array 7-97.5.1 Removing the Front Bezel and Ear Caps1. Use the provided key to unlock both bezel locks.2. Grasp the front b

Pagina 22

7-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 23

8-1CHAPTER8Troubleshooting Your ArrayThis chapter covers the following maintenance and troubleshooting topics: “Sensor Locations” on page 8-1 “Sil

Pagina 24 - SANnet II 200 SATA Arrays

xii SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005FIGURE 4-20 SANnet II 200 SATA Array Default Sin

Pagina 25

8-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20058.1.1 Cooling Element SensorsThere are two fans

Pagina 26 - Configurations

Chapter 8 Troubleshooting Your Array 8-38.1.2 Temperature SensorsExtreme high and low temperatures can cause significant damage if they go unnoticed.

Pagina 27

8-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20058.1.3 Voltage SensorsVoltage sensors make sure t

Pagina 28 - 1.2 Field-Replaceable Units

Chapter 8 Troubleshooting Your Array 8-58.1.4 Power Supply SensorsEach SANnet II 200 FC, SATA, and SATA SE array has two fully redundant power supplie

Pagina 29 - 1.2.3 Disk Drives

8-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – It is important to know the cause of the

Pagina 30 - 1.2.4 Battery Module

Chapter 8 Troubleshooting Your Array 8-72. Depending on whether the cause of the alarm is a failed component or a controller event and which applicati

Pagina 31 - 1.3 Interoperability

8-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005 The surviving controller sends event messages

Pagina 32 - 1.4.3 Fibre Hubs and Switches

Chapter 8 Troubleshooting Your Array 8-9If a double drive failure has occurred, it might be possible to recover by performing the following steps:1. D

Pagina 33 - 1.4.5 Scalability

8-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005 If the status is still “FATAL FAIL,” you migh

Pagina 34 - 1.5.1.1 Host Bus Adapters

Chapter 8 Troubleshooting Your Array 8-118.7 Troubleshooting FlowchartsThis section provides troubleshooting flowcharts to illustrate common troublesh

Pagina 35 - 1.6 Additional Software Tools

Figures xiiiFIGURE B-3 SANnet II 200 FC JBOD Array Attached to Two HBA Ports . . . . . . . . . . . . . . . . B–8FIGURE B-4 JBOD or Expansion Unit Tro

Pagina 36

8-12 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 8-2 Power Supply or Fan Module Flowchart

Pagina 37 - Site Planning

Chapter 8 Troubleshooting Your Array 8-13Figure 8-3 Power Supply or Fan Module Flowchart, 2 of 28.7.2 Drive LEDsBefore you perform the drive LED troub

Pagina 38 - 2.2 Safety Precautions

8-14 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005For overview information about drive LEDs and h

Pagina 39 - Operating Nonoperating

Chapter 8 Troubleshooting Your Array 8-15Figure 8-4 Drive LEDs Flowchart, 1 of 2Is onlyone drive LEDamber?Check View andEdit SCSIdrives menu.Rotate dr

Pagina 40 - 2.6 Layout Map

8-16 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 8-5 Drive LEDs Flowchart, 2 of 2For more

Pagina 41 - 2.6.2 Tabletop Placement

Chapter 8 Troubleshooting Your Array 8-17Figure 8-6 Front-Panel LEDs Flowchart, 1 of 4 3A Front panel LEDs problem (FC)Allfront panelLEDs

Pagina 42

8-18 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 8-7 Front-Panel LEDs Flowchart, 2 of 4

Pagina 43 - Chapter 2 Site Planning 2-7

Chapter 8 Troubleshooting Your Array 8-19Figure 8-8 Front-Panel LEDs Flowchart, 3 of 4 3C Front panel LEDs problem (FC)Is Temp LEDamber?Ye

Pagina 44

8-20 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 8-9 Front-Panel LEDs Flowchart, 4 of 4

Pagina 45 - Unpacking Your Array

Chapter 8 Troubleshooting Your Array 8-218.7.4 I/O Controller ModuleThe following flowchart provides troubleshooting procedures for the I/O controller

Pagina 46 - 3.2.1 Standard Array Packages

xiv SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 47 - 3.4 Customer-Provided Cables

8-22 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 48

A-1APPENDIXASANnet II 200 FC, SATA, and SATA SE Array SpecificationsThis appendix provides the specifications for the SANnet II 200 FC, SATA, and SATA

Pagina 49 - Connecting Your Array

A-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – Add 12.75 lb (5.8 kg) for packaging if yo

Pagina 50 - Cannot Be Removed

Appendix A SANnet II 200 FC, SATA, and SATA SE Array Specifications A-3The following topics briefly describe specific hardware and firmware features.

Pagina 51

A-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005A.2.3 Firmware LUN Filtering (RAID-Based Mapping

Pagina 52 - 4.2 RAID Array Connections

Appendix A SANnet II 200 FC, SATA, and SATA SE Array Specifications A-5Australia Part of World-wide CB SchemeArgentina Resolution 92-98 (S-Mark)German

Pagina 53 - II 200 SATA array

A-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 54 - SATA Array

B-1APPENDIXBUsing a Standalone JBOD Array (SANnet II 200 FC Array Only)A single SANnet II 200 FC JBOD array can be connected directly to certain Solar

Pagina 55 - FC device connections

B-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005B.2 Supported Operating Systems (JBOD Arrays)The

Pagina 56

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-3 SANscape software supports FC JBOD arrays. However, since FC JBOD arrays d

Pagina 57

xvTablesTAB LE 1-1 Comparison of SANnet II 200 FC, SATA, and SATA SE Array Features . . . . . . . . 1–5TAB LE 1-2 SANnet II 200 FC, SATA, and SATA SE

Pagina 58 - Pin Number Voltage Color

B-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005B.5.1.1 Enabling JBOD SupportTo monitor peripher

Pagina 59

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-5Figure B-1 ID SwitchBy default, the ID switch on all SANnet II 200 FC JBOD

Pagina 60

B-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Caution – The loop ID should only be changed whi

Pagina 61

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-7Figure B-2 SANnet II 200 FC JBOD Array Attached to a Single HBA PortIn this

Pagina 62 - Bezel locks

B-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure B-3 shows an example of a SANnet II 200 F

Pagina 63

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-9Caution – Be careful not to mount the same drive twice if you are not using

Pagina 64 - LEDs Displayed

B-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051. Connect a fiber-optic cable to an HBA.2. Set

Pagina 65

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-114. Click OK. The JBOD array is displayed in the main window.In a single-bus

Pagina 66 - Two ports on channel 3

B-12 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005B.10 Resizing LUNs Greater Than 1 TbyteWhen a L

Pagina 67 - Two drive ports on channel 3

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-13B.11.1 Troubleshooting Configuration IssuesFollow this sequence of general

Pagina 68 - Host channel 5

xvi SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005TA BL E 6 -6 Power Supply LEDs . . . . . . . .

Pagina 69 - 4.8.3 Default SFP Placement

B-14 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005 SANscape CLI event log For expansion units,

Pagina 70

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-15Figure B-4 JBOD or Expansion Unit Troubleshooting Flowchart, 1 of 2Drive l

Pagina 71

B-16 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure B-5 JBOD or Expansion Unit Troubleshoot

Pagina 72 - Default SFP Placement

C-1APPENDIXCFailed Component Alarm CodesThis appendix describes failed component alarm codes. Failed component alarm codes use Morse code dot and dash

Pagina 73

C-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005See “Front-Panel LEDs” on page 6-2 for more info

Pagina 74 - RAID Array

D-1APPENDIXDCable PinoutsThis appendix identifies the pinouts for each connector used in the SANnet II 200 FC, SATA, and SATA SE arrays. Topics covere

Pagina 75 - Change/Set IP Address ?

D-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005D.2 DB9 COM PortThe COM port is a female DB9 con

Pagina 76 - Ethernet

E-1APPENDIXEConfiguring a Sun Server Running the Solaris Operating SystemThis appendix provides access information and LUN setup information needed wh

Pagina 77 - # telnet IP-address

E-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure E-1 RAID Array COM Port Connected Locall

Pagina 78

Appendix E Configuring a Sun Server Running the Solaris Operating System E-3E.3 Determining the WWN in the Solaris Operating SystemPerform the followi

Pagina 79

Preface xviiPrefaceThis manual provides instructions for installing, initially configuring, and operating the SANnet II 200 Fibre Channel (FC), SANnet

Pagina 80 - 4.16 Power-On Sequence

E-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 81 - 4.17 Powering Off the Array

F-1APPENDIXFConfiguring a Microsoft Windows ServerThis appendix provides platform-specific host installation and configuration information to use when

Pagina 82

F-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – A DB9-to-DB25 serial cable adapter is inc

Pagina 83 - Configuration Overview

Appendix F Configuring a Microsoft Windows Server F-3 1 stop bit No parity8. To save the connection and its settings, choose File → Save.The connec

Pagina 84

F-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005F.2 Accessing the Firmware Application From a Mi

Pagina 85

Appendix F Configuring a Microsoft Windows Server F-5c. Select the Disk Management folder.d. If a Write Signature and Upgrade Disk Wizard is displayed

Pagina 86

F-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20058. Specify the amount of disk space to use or ac

Pagina 87 - host IDs to

Appendix F Configuring a Microsoft Windows Server F-7c. Click Next.A confirmation dialog box displays the settings you have specified.11. Click Finish

Pagina 88

F-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005F.4 Determining the Worldwide Name for Microsoft

Pagina 89 - Switches

G-1APPENDIXGConfiguring a Linux ServerThis appendix provides access information and LUN setup information needed when you connect a FC, SATA, or SATA

Pagina 90 - Two Switches

xviii SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Appendix E provides instructions on configurin

Pagina 91

G-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051. Use a null modem cable to communicate via the

Pagina 92

Appendix G Configuring a Linux Server G-3d. If E is not correct, press the letter E and the cursor goes to line E. Backspace and change the line to: A

Pagina 93 - Server 4

G-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005G.3 Checking the Adapter BIOSWhen booting the se

Pagina 94

Appendix G Configuring a Linux Server G-512. Press Escape until a screen is displayed that says “Configuration setting modified.” Highlight Save chang

Pagina 95

G-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051. To list all devices and their paths, start a

Pagina 96 - 5.2 Larger Configurations

Appendix G Configuring a Linux Server G-72. Take the device that you ran fdisk on and run the following command to create an ext3 file system:where x

Pagina 97

G-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20053. Save the file.4. To verify that fstab was set

Pagina 98

H-1APPENDIXHConfiguring an IBM Server Running the AIX Operating SystemThis appendix provides platform-specific host installation and configuration inf

Pagina 99 - Checking LEDs

H-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005If you are planning to access your array over an

Pagina 100 - 6.2 Front-Panel LEDs

Appendix H Configuring an IBM Server Running the AIX Operating System H-3Figure H-1 RAID Array COM Port Connected Locally to the Serial Port of a Hos

Pagina 101 - LED LED Color Description

Preface xixTechnical SupportFor late-breaking Release Notes and all manuals for this product, go to the SANnet II SCSI array section, or the SANnet

Pagina 102 - 6.2.1 Drive LED Status

H-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005H.3 Identifying the Device on Which You Will Cre

Pagina 103 - 6.3 Back-Panel LEDs

Appendix H Configuring an IBM Server Running the AIX Operating System H-52. Choose System Storage Management (Physical and Logical Storage) from the S

Pagina 104

H-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20057. Choose Activate a Volume Group from the Volum

Pagina 105 - Chapter 6 Checking LEDs 6-7

Appendix H Configuring an IBM Server Running the AIX Operating System H-77. Move the cursor to highlight the name of the volume group you created in “

Pagina 106

H-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20053. Display the attributes of the new file system

Pagina 107 - Chapter 6 Checking LEDs 6-9

I-1APPENDIXIConfiguring an HP Server Running the HP-UX Operating SystemThis appendix provides platform-specific host installation and configuration in

Pagina 108

I-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005If you are planning to access your array over an

Pagina 109 - Maintaining Your Array

Appendix I Configuring an HP Server Running the HP-UX Operating System I-3FIGURE I-1 RAID Array COM Port Connected Locally to the Serial Port of a Hos

Pagina 110 - 7.1.2 In-Band Connections

I-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005I.3 Attaching the Disk ArrayThe simplest way to

Pagina 111 - 7.1.4 Enabling VERITAS DMP

Appendix I Configuring an HP Server Running the HP-UX Operating System I-5As with many system administration tasks, you can use SAM to create and main

Pagina 112 - 7.2 Battery Operation

CopyrightCopyright  2001-2005 Dot Hill Systems Corp. All rights reserved. No part of this publication may be reproduced, stored in a retrieval syste

Pagina 113

xx SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Dot Hill Welcomes Your CommentsDot Hill is intere

Pagina 114

I-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20053. Initialize each partition as an LVM disk with

Pagina 115 - 7.4 Upgrading Firmware

Appendix I Configuring an HP Server Running the HP-UX Operating System I-7In the output of vgdisplay, the Total PE field displays the number of physic

Pagina 116

I-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Both character and block device files for the ne

Pagina 117

Appendix I Configuring an HP Server Running the HP-UX Operating System I-92. To include the file system created in the example, add the following line

Pagina 118

I-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20052. Type:Output similar to the following is disp

Pagina 119 - Troubleshooting Your Array

1IndexAaddressIP 4–25agentAgent Options Management window B–10alarmsfailed component description C–1silencing 8–6amber blinking on Event LED 6–4arbitr

Pagina 120 - 8.1.1 Cooling Element Sensors

2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Solaris E–1Windows F–1Windows 2000 server or Windo

Pagina 121 - 8.1.2 Temperature Sensors

Index 3host channels 4–16data transfer speedSANnet II 200 FC Array 4–19SANnet II 200 SATA Array 4–20limitations 4–20host configurationLinux G–1Solaris

Pagina 122 - 8.1.3 Voltage Sensors

4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005powering up an array 4–16Powering Up and Checking

Pagina 123 - 8.2 Silencing Audible Alarms

Index 5WWindowsaccessing firmware from F–4determining worldwide name F–8recognizing new devices and LUNs F–4worksheetpreinstallation 2–6worldwide name

Pagina 124

1-1CHAPTER1Product and Architecture OverviewThis manual describes the SANnet II 200 FC, SATA, and SATA Special Edition (SE) arrays.The FC, SATA, and S

Pagina 125 - 8.4 Controller Failover

6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 126

1-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051.1 Comparison of FC, SATA, and SATA SE ArraysFi

Pagina 127

Chapter 1 Product and Architecture Overview 1-31.1.1 Fibre Channel and SATA Array ArchitecturesThe FC, SATA, and SATA SE share many architectural elem

Pagina 128 - ■ Resets the array

1-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051.1.1.2 SANnet II 200 SATA and SATA SE Array Fea

Pagina 129 - ■ “Drive LEDs” on page 8-13

Chapter 1 Product and Architecture Overview 1-5Note – Although the products are very similar in appearance and setup, the configurations have very imp

Pagina 130 - Power supply or fan problem

1-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Caution – In FC and SATA configurations with lar

Pagina 131 - 8.7.2 Drive LEDs

Chapter 1 Product and Architecture Overview 1-7Table 1-2 shows the configuration options for SANnet II 200 FC, SATA, and SATA SE arrays.A label on the

Pagina 132

1-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005in a JBOD array. For example, “SANnet II 200 D10

Pagina 133 - Drive LEDs problem (FC)

Chapter 1 Product and Architecture Overview 1-9Specific Integrated Circuit (ASIC) controller chips handle the interconnection between the controller b

Pagina 134 - 8.7.3 Front-Panel LEDs

iiiContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii1. Produc

Pagina 135 - 3A

1-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Caution – You can mix disk drive capacity in th

Pagina 136 - 3B

Chapter 1 Product and Architecture Overview 1-111.2.5 Power and Fan ModulesNote – The SATA arrays can only be ordered in an AC configuration. However,

Pagina 137 - 3C

1-12 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051.4.1 FC ProtocolsTwo common protocols are used

Pagina 138 - 3D

Chapter 1 Product and Architecture Overview 1-13A fabric switch functions as a routing engine, which actively directs data transfers from source to de

Pagina 139 - 8.7.4 I/O Controller Module

1-14 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051.5 Fibre Channel ArchitectureEach RAID array h

Pagina 140

Chapter 1 Product and Architecture Overview 1-151.5.1.2 Active-to-Active Redundant ControllerIn active-to-active redundant controller mode, the primar

Pagina 141 - Specifications

1-16 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 142 - Highlights

2-1CHAPTER2Site PlanningThis chapter outlines the site planning requirements and basic safety requirements for the installation and use of the FC arra

Pagina 143 - A.2.1 Hardware Loop ID

2-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005The customer is responsible for meeting all gove

Pagina 144 - Product Safety Standard

Chapter 2 Site Planning 2-32.3 Environmental Requirements2.3.1 Electromagnetic Compatibility The following is required for all installations: All AC

Pagina 145 - Test Standard

iv SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051.5 Fibre Channel Architecture . . . . . . . . .

Pagina 146

2-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20052.5 Physical SpecificationsUse the physical spec

Pagina 147 - 200 FC Array Only)

Chapter 2 Site Planning 2-5 Route interface cables away from motors and other sources of magnetic or radio frequency interference. Stay within the c

Pagina 148 - JBOD Arrays

2-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – SANnet II family arrays require at least

Pagina 149 - B.5.1 SANscape

Chapter 2 Site Planning 2-7Table 2-4 Site Preparation WorksheetRackmounting Customers must ensure that the appropriate service outlets are available

Pagina 150 - JBOD Array

2-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Table 2-5 Host and Fabric Switch Connectivity S

Pagina 151 - Press to change the ID number

3-1CHAPTER3Unpacking Your ArrayThis chapter describes the procedure for unpacking your FC, SATA, or SATA SE array package. The following topics are co

Pagina 152

3-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20056. Check the list of “Customer-Provided Cables”

Pagina 153

Chapter 3 Unpacking Your Array 3-33.3 Field-Replaceable UnitsCheck that you received all field-replaceable units (FRUs) ordered with your array. For a

Pagina 154 - JBOD array

3-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 155 - Host Computer

4-1CHAPTER4Connecting Your ArrayThis chapter describes procedures for cabling a FC, SATA, or SATA SE array and for connecting an array to power and to

Pagina 156

Contents v4.4 Connecting the Chassis to DC Power Outlets . . . . . . . . . . . . . . . . . . . . . . . . . 4–94.5 Cabling to Expansion Units . . . . .

Pagina 157

4-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Before you connect the array to the network, pos

Pagina 158

Chapter 4 Connecting Your Array 4-34. Lift the pawl off the threaded part of the lock body, as shown in the second panel of Figure 4-2.Figure 4-2 Sequ

Pagina 159 - ■ SANscape event log

4-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20059. Replace the bezel.Note – To convert your beze

Pagina 160 - ■ SANscape CLI event log

Chapter 4 Connecting Your Array 4-5Figure 4-3 Hardware Connections on the Back of a Dual-Controller SANnet II 200 FC Array4.2.2 SANnet II 200 SATA Arr

Pagina 161

4-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 4-4 Hardware Connections on the Back of

Pagina 162

Chapter 4 Connecting Your Array 4-74.2.3 SANnet II 200 SATA SE Array ConnectionsFigure 4-5 identifies the hardware connections on the back of a dual-c

Pagina 163 - Failed Component Alarm Codes

4-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20051. Use a Phillips screwdriver to remove the scre

Pagina 164

Chapter 4 Connecting Your Array 4-9Figure 4-6 Installing a Cord Lock4.4 Connecting the Chassis to DC Power OutletsNote – The SANnet II 200 SATA array

Pagina 165 - Cable Pinouts

4-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20052. Connect a DC power cable to the first power

Pagina 166 - D.2 DB9 COM Port

Chapter 4 Connecting Your Array 4-114.5 Cabling to Expansion UnitsThe instructions in this section apply to the SANnet II 200 FC and the SANnet II 200

Pagina 167 - Solaris Operating System

vi SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20056.2.1 Drive LED Status . . . . . . . . . . . . .

Pagina 168 - # tip -38400 /dev/ttyb

4-12 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 4-7 SANnet II 200 FC Array Attached to

Pagina 169 - 1. Reboot the computer

Chapter 4 Connecting Your Array 4-13Figure 4-8 SANnet II 200 SATA Array Attached to Two Hosts and Two Expansion Units4.6 Setting Loop IDs on Expansion

Pagina 170

4-14 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 4-9 Front Bezel and Front Bezel Locks o

Pagina 171 - APPENDIX

Chapter 4 Connecting Your Array 4-15Ensure that the loop IDs of expansion units do not duplicate the loop IDs of other connected expansion units or RA

Pagina 172 - ■ 8 data bits

4-16 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20058. Lift the bezel into position and press it on

Pagina 173 - ■ No parity

Chapter 4 Connecting Your Array 4-17labeled FC0, FC1, FC4, and FC5 to indicate channels 0, 1, 4, and 5. Default configurations do not include an SFP c

Pagina 174 - Microsoft Windows Server

4-18 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – The SANnet II 200 SATA SE array configur

Pagina 175

Chapter 4 Connecting Your Array 4-19Figure 4-13 Dedicated Drive Channels 2 and 3 (on Both Controllers) in a Dual-Controller SANnet II 200 SATA Array 4

Pagina 176

4-20 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 4-14 Host Channels on a Dual-Controller

Pagina 177

Chapter 4 Connecting Your Array 4-21Figure 4-15 Host Channels on a Dual-Controller SANnet II 200 SATA ArrayThe following figure shows the host channel

Pagina 178 - Windows Servers

Contents vii8.5 Recovering From Fatal Drive Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8–88.6 Using the Reset Push Button

Pagina 179 - Configuring a Linux Server

4-22 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005To review various configuration options, see th

Pagina 180

Chapter 4 Connecting Your Array 4-23No SFPs are plugged into the drive channels. This configuration is appropriate for connecting to up to four hosts

Pagina 181 - Linux Server

4-24 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 4-21 SANnet II 200 FC JBOD/Expansion Uni

Pagina 182 - G.3 Checking the Adapter BIOS

Chapter 4 Connecting Your Array 4-25Figure 4-23 Typical SFP Connector Used to Connect Cables to Chassis SFP Ports4.9 Establishing Communications With

Pagina 183

4-26 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005 Use the show network-parameters CLI command.

Pagina 184 - G.6 Creating a File System

Chapter 4 Connecting Your Array 4-274.11 Manually Setting a Static IP AddressYou can manually set an array’s IP address using the controller’s firmwar

Pagina 185 - System Manually

4-28 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20058. Choose Ye s to reset the controller.The cont

Pagina 186

Chapter 4 Connecting Your Array 4-29Note – Alternatively, you can use the Solaris operating system tip command or a terminal emulation program to acce

Pagina 187 - Operating System

4-30 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Carefully consider the following limitations of

Pagina 188 - IBM Server Running AIX

Chapter 4 Connecting Your Array 4-316. Verify the SES/PLD (programmable logic device) version of the expansion unit and the RAID array.To review the v

Pagina 189 - COM port

viii SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005E.2 Using the tip Command for Local Access to t

Pagina 190 - Recognize New LUNs

4-32 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – The connection of a FC, SATA, or SATA SE

Pagina 191 - H.5 Creating a Volume Group

Chapter 4 Connecting Your Array 4-334.17 Powering Off the ArrayYou might need to power off the array (both power supplies) if you relocate the array o

Pagina 192 - H.7 Creating a File System

4-34 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 193

5-1CHAPTER5Configuration OverviewThis chapter highlights the tools and the important limitations and guidelines which must be understood prior to conf

Pagina 194 - Servers Running AIX

5-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20053. Set up an IP address for the controller. See

Pagina 195 - HP-UX Operating System

Chapter 5 Configuration Overview 5-3Note – Each operating system has a method for recognizing storage devices and LUNs and might require the use of sp

Pagina 196 - HP Server Running HP-UX

5-4 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Caution – If you keep the default loop mode and

Pagina 197

Chapter 5 Configuration Overview 5-5attaching the cables for a LUN-mapped channel pair, make sure that the first channel is connected to the upper por

Pagina 198 - I.4 Logical Volume Manager

5-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Note – Multipathing for FC, SATA, and SATA SE ar

Pagina 199 - # ioscan -fnC disk

Chapter 5 Configuration Overview 5-7Figure 5-1 A Point-to-Point Configuration with a Dual-Controller SANnet II 200 FC Array and Two Switches

Pagina 200 - I.7 Creating a Volume Group

Contents ixI.3 Attaching the Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I–4I.4 Logical Volume Manag

Pagina 201 - I.8 Creating a Logical Volume

5-8 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 5-2 A Point-to-Point Configuration With a

Pagina 202

Chapter 5 Configuration Overview 5-9Perform the following steps to set up a typical point-to-point SAN configuration based on Figure 5-1 and Figure 5-

Pagina 203

5-10 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 20057. Map logical drive 0 to channels 0 and 1 of t

Pagina 204 - 2. Type:

Chapter 5 Configuration Overview 5-11Figure 5-3 A DAS Configuration With Four Servers, a Dual-Controller SANnet II 200 FC Array, and Two Expansion Un

Pagina 205

5-12 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005Figure 5-4 A DAS Configuration With Four Serve

Pagina 206

Chapter 5 Configuration Overview 5-13DAS configurations are typically implemented using a fabric loop (FL_port) mode. A loop configuration example is

Pagina 207

5-14 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 200511. Connect the first server to port FC 0 of th

Pagina 208

Chapter 5 Configuration Overview 5-15 Do not combine SANnet II 200 FC drives and SANnet II 200 SATA drives on the same Fibre Channel loop. Use them o

Pagina 209

5-16 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Pagina 210

6-1CHAPTER6Checking LEDsThis chapter describes the front and back-panel LEDs, which display the operating status of all drives and modules. Topics cov