8-20 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual March 2005
Figure 8-9 Front-Panel LEDs Flowchart, 4 of 4
3D
Front panel LEDs problem (FC)
Check that LED
ribbon cable in right
ear is not loose.
Verify the air
conditioning is
working properly.
Fix if needed.
End
Ye s
Resolved?
Temp LED
Resolved?
No
No
Replace controller
that reported over
temperature error.
Resolved?
Replace chassis.
Ensure adequate
ventilation.
Resolved?
Ye s
End
EndYe s
Ye s
No
No
End
--Reseat the FRU that is not operating correctly.
--Swap the questionable FRU with a known-good
FRU from the same array.
Notes
55 degrees Celsius equals 131 degrees
Fahrenheit.
Prior to replacing a chassis, try the following: