Dot Hill Systems SANnet II 200 Manual de servicio Pagina 151

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 210
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 150
Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-5
Figure B-1 ID Switch
By default, the ID switch on all SANnet II 200 FC JBOD arrays is set to 1 so the range
of IDs is automatically 16 to 31. You can leave the ID switch set to 1, or set it for
whichever range of IDs you prefer.
The ID switch offers eight ID ranges. Each set contains 16 IDs. The last 4 IDs in each
range are ignored. These ranges are shown in Table B-2.
B.6.1 Changing Your ID Switch Setting
Perform the following steps to change your ID switch setting:
1. Remove the bezel (the front faceplate).
See “Replacing the Front Bezel and Ear Caps” on page 7-8 for step-by-step
instructions for removing and replacing the front bezel and ear caps.
Caution – The plastic ear covers are snap-on parts that require care when you remove
them. If you remove the right plastic ear cap, take care to avoid breaking the Reset
push button directly below the ear cap.
2. Remove the left plastic ear cap from the front of the chassis.
3. Use the buttons to change the ID number.
Table B-2 ID Switch Settings for SANnet II 200 FC JBOD Arrays
ID Switch Setting Range of IDs
0 0–15
1 16–31
2 32–47
3 48–63
4 64–79
5 80–95
6 96–111
7 112–125
Press to change the ID number