Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-13
B.11.1 Troubleshooting Configuration Issues
Follow this sequence of general steps to isolate software and configuration issues.
1. Look for storage-related messages in
/var/adm/messages and identify any suspect
SANnet II 200 FC JBOD arrays and fibre loops.
2. Check your SANscape console for alerts or messages.
3. Check revisions of software package, patches, and hardware.
4. Verify correct device file paths.
B.11.2 Troubleshooting Hardware Issues
When a problem is not otherwise reproducible, suspect hardware might need to be
replaced. Always make only one change at a time and carefully monitor results. When
possible, it is best to restore the original hardware before replacing another part to
eliminate the introduction of additional unknown problem sources.
After hardware replacement, a problem can usually be considered solved if it does not
resurface during a period equal to twice its original frequency of occurrence. For
example, if a problem was occurring once a week on average before a potential fix was
made, running two weeks without seeing the problem again suggests a successful fix
took place.
Troubleshooting hardware problems is usually accomplished by an FRU isolation
sequence that uses the process of elimination. Set up a minimal configuration that
shows the problem and then replace elements in this order, testing after each
replacement until the problem is solved:
1. Replace the cables.
2. Replace the SFPs.
3. Replace the drives.
4. Replace the HBAs.
Often you can also find out what does cause a hardware problem by determining the
elements that do not cause it. Start out by testing the smallest configuration that does
work, and then keep adding components until a failure is detected.
To view error messages reported by JBODs or expansion units, use any of the
following:
Message log in the operating system
For Solaris, var/adm/messages
For Linux, var/log/messages
For Microsoft Windows, use the event viewer
SANscape event log