Dot Hill Systems SANnet II 200 Manual de servicio Pagina 135

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 210
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 134
Chapter 8 Troubleshooting Your Array 8-17
Figure 8-6 Front-Panel LEDs Flowchart, 1 of 4
3A
Front panel LEDs problem (FC)
All
front panel
LEDs flashing
amber?
Ye s
LEDs stop
flashing?
No
Are all the
LEDs off during
operation?
Is the power
switch on?
Ye s
No
Is the power
connected?
Is the
power cord
well seated?
Resolved?Ye s Ye s Ye s
Turn it on.
No
Connect it.
No
Seat it.
No
Ye s
No
No
Replace chassis.
Continue with
3B.
Adjust end cap to ensure
reset button is not depressed.
Remove the right end cap.
Check that the Reset button
is not jammed.
Check that LED ribbon cable
in right ear is not loose.
Replace the end cap.
Ye s
Refer to
FRU Installation
Guide for
instructions
No
Is the LED
ribbon cable on the
right ear loose?
Secure the
ribbon cable.
Replace chassis.
Ye s
End
End
--Reseat the FRU that is not operating correctly.
--Swap the questionable FRU with a known-good
FRU from the same array.
Notes
Prior to replacing a chassis, try the following: